Advanced Leak Detection

FLIR Si2-Pro™

The FLIR Si2-Pro helps you significantly lower costs associated with mechanical bearing issues and partial discharge on electrical equipment. It also enables you to drastically reduce leaks in your facilities, cutting down expenses related to compressed air and gas leaks. With the Si2 series, you'll experience the best-in-class performance, decision support, fleet management, and enterprise data integration available.

For specialized needs, you can choose from additional models: opt for the Si2-LD for advanced leak detection and mechanical fault detection applications or select the Si2-PD for your electric utility applications. Explore these models in the related products section below to find the perfect fit for your requirements.

Request Info
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

The FLIR Si2-Pro™ is an industrial-grade acoustic imaging camera designed to revolutionise maintenance and inspection workflows. Equipped with 124 MEMS microphones and AI-powered severity assessment, it excels in detecting partial discharges, pressurised air/gas leaks, and mechanical faults. 

With built-in frequency tuning, precise leak quantification, and enterprise-level fleet management, this IP54-rated camera is an indispensable tool for industries focused on safety, efficiency, and cost savings.

The FLIR Si2-Pro™ is perfect for various industrial applications, including:

Leak Detection: Identify and measure compressed air, gas, and other leaks from up to 200m away, minimizing energy losses and operational costs.

Mechanical Fault Analysis: Detect bearing defects, misalignment, and other mechanical issues early to prevent equipment failures and reduce downtime.

Partial Discharge Detection: Pinpoint electrical discharges in high-voltage systems, assess their severity, and classify PD types for targeted maintenance.

To maintain the FLIR Si2-Pro™ in peak condition:

• Regularly clean the camera’s sensors and microphones using appropriate tools to ensure precise measurements.

• Store the device in its provided hard transport case to protect it from dust, moisture, and physical damage.

• Update the camera firmware via OTA (Over-The-Air) updates to access the latest features and fixes.

• Schedule routine calibration and servicing to ensure long-term accuracy and performance.

Key Feature

Mechanical fault detection for early identification of bearing problems, preventing costly downtime

Key Feature

Quantify leak rate and cost of industrial gas and compressed air leaks, to prioritize repair and calculate savings

Key Feature

On-camera and in-software severity assessment and type classification of partial discharge (PD) issue

Specifications
The technical specifications of the FLIR Si2-Pro™ are as follows.
IR Resolution
240 × 180 pixels (43,200 pixels)
Thermal Sensitivity/NETD
<0.06°C (0.11°F) / <50 mK at 30°C (86°F)
Accuracy
±2°C (±3.6°F) or ±2% of reading, for ambient temperature 10°C to 35°C (50°F to 95°F) and object temperature above 0°C (32°F)
Field of view (FOV)
33° × 25°
Digital Camera
5 MP
Image Modes
Thermal MSX, Thermal, Picture-in-Picture, Digital camera
Display
3.5 inches
640 × 480 color LCD
Storage Media
Internal memory and onboard FLIR Ignite cloud connectivity (with Wi-Fi)

Download Brochure

Find out more about the specifications of this product